Study on γH2AX expression of lymphocytes as a biomarker in radiation biodosimetry


Chinese Center for Disease Control and Prevention Key Laboratory of Radiological Protection and Nuclear Emergency; National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention; Chinese Center for Medical Response to Radiation Emergency, Ministry of Health, Beijing 100088, PR China

Correspondence Address:
Jian Xiang Liu
No. 2 Xinkang Street, Deshengmenwai, Xicheng, Beijing 100088
PR China
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2041-9414.197167

Rights and Permissions

Flow cytometry analysis was used to detect the changes of γH2AX protein expression in human peripheral blood lymphocytes. In the dose-effect study, the expression of γH2AX was detected 1 h after irradiation with 60Co γ-rays at doses of 0, 0.5, 1, 2, 4, and 6 Gy. Blood was cultivated for 0, 1, 2, 4, 6, 12, and 24 h after 4 Gy 60Co γ-rays irradiation for the time-effect study. At the same time, the blood was divided into four treatment groups (ultraviolet [UV] irradiation, 60Co γ-rays irradiation, UV plus 60Co γ-rays irradiation, and control group) to detect the changes of protein expression of γH2AX. The results showed that the γH2AX protein expression was in dose-effect and time-effect relationship with 60Co γ-rays. The peak expression of γH2AX was at 1 h after 60Co γ-ray irradiation and began to decrease quickly. Compared to irradiation with 60Co γ-rays alone, the expression of γH2AX was not significantly changed after irradiation with 60Co γ-rays plus UV. Dose rate did not significantly change the expression of γH2AX. The expression of γH2AX induced by 60Co γ-rays was basically consistent with the mice in vivo and in vitro. The results revealed that the detection of γH2AX protein expression changes in peripheral blood lymphocyte by flow cytometry analysis is reasonable and may be useful for biodosimetry.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed6445    
    Printed783    
    Emailed0    
    PDF Downloaded543    
    Comments [Add]    
    Cited by others 4    

Recommend this journal