Establishment of dose-response curves for dicentrics and premature chromosome condensation for radiological emergency preparedness in Thailand


Benchawan Rungsimaphorn1, Budsaba Rerkamnuaychoke3, Wanwisa Sudprasert2 
1 Department of Applied Radiation and Isotopes, Faculty of Science, Kasetsart University; Department of Pathology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
2 Department of Applied Radiation and Isotopes, Faculty of Science, Kasetsart University, Bangkok, Thailand

Correspondence Address:
Wanwisa Sudprasert
Department of Applied Radiation and Isotopes, Faculty of Science, Kasetsart University, 50 Ngam Wong Wan Road, Chatuchak, Bangkok 10900
Thailand

The in vitro dose calibration curves using conventional biological dosimetry – dicentric chromosome assay (DCA) and premature chromosome condensation (PCC) assay – were performed for the first time in Thailand for reconstruction of radiation dose in the exposed individuals. The peripheral blood lymphocyte samples from healthy donors were irradiated with 137Cs source at a dose rate of 0.652 Gy/min to doses of 0.1, 0.25, 0.5, 0.75, 1, 2, 3, 4, and 5 Gy for DCA technique, and 5, 10, 15, 20, and 25 Gy for PCC technique. The blood samples were cultured and processed following the standard procedure as prescribed in the International Atomic Energy Agency report with slight modifications. The yield of dicentrics with dose from at least 1000 metaphases or 100 dicentrics was fitted to a linear quadratic model using Chromosome Aberration Calculation Software (CABAS, version 2.0) whereas those of PCC rings with dose from 100 rings was fitted to a linear quadratic equation at doses from 0 to 15 Gy. These curves will be useful for in vitro dose reconstruction and can support the preparedness for overexposure to radiation among public or occupational workers and eventual radiological accident in Thailand.


How to cite this article:
Rungsimaphorn B, Rerkamnuaychoke B, Sudprasert W. Establishment of dose-response curves for dicentrics and premature chromosome condensation for radiological emergency preparedness in Thailand.Genome Integr 2016;7:8-8


How to cite this URL:
Rungsimaphorn B, Rerkamnuaychoke B, Sudprasert W. Establishment of dose-response curves for dicentrics and premature chromosome condensation for radiological emergency preparedness in Thailand. Genome Integr [serial online] 2016 [cited 2024 Mar 28 ];7:8-8
Available from: https://www.genome-integrity.org/article.asp?issn=2041-9414;year=2016;volume=7;issue=1;spage=8;epage=8;aulast=Rungsimaphorn;type=0